Author: Lee Fu-min Handan Iron and Steel Group Company Automation Engineering Technology Center, Handan [Abstract] article from the Project Overview, control technology requirements, control design, application notes, using the results and other details of the application Yudian products in the 450m3 blast furnace production. Practice has proved that the UAV operator/servo amplifier provides a good automation guarantee for the stable production and high output of the blast furnace. [Keywords] 450m3 blast furnace top pressure control hot air temperature control project overview A 450m3 blast furnace of a steel plant began construction in October 2005, and officially produced iron at the end of June 2006, producing 450,000 tons of iron per year, with a utilization factor of 3.0. After technical demonstration, from the comprehensive cost-effectiveness of the system, the basic automation control system of blast furnace and hot blast stove selected Schneider's QUANTUM series PLC products. The main instrument selected Xiamen AI-708J operator/servo amplifier with 2-in-1 function. The control process requires the top pressure control function: maintaining the stability of the top pressure of the blast furnace is a primary task of the blast furnace production operation. Stabilizing the top pressure can stabilize the gas flow and promote the antegrade blast. Therefore, in the operation, it is necessary to adjust the valve position of the top pressure regulating valve in time so that it can stabilize the top pressure and avoid fluctuations in the top and bottom peaks, thereby avoiding fluctuations in the furnace condition. The top pressure of the 450m3 blast furnace is generally stable at 90±5 KPa. Selection: This is the most important regulating valve in blast furnace production. Because of the frequent adjustment of this valve and high pipeline pressure, the control quality of the valve is the highest. The top pressure regulating valve is generally used by three valves in parallel to form a valve group. The valve block typically has a relatively small diameter valve for flexible control. Control mode: The three sets of valves are usually manually opened to a fixed angle by two valves, and the third valve is automatically controlled. The control signal direction is: PLC-AO output template-3 road 4~20mA signal-AI-708J- regulating valve. The top pressure regulating valve process diagram is shown in Figure 1: Valve 1 Valve 2 Gas blasting valve after blast furnace dust removal 3 Figure 1 Hot air temperature control function: By automatically adjusting the mixing valve opening degree, the appropriate ratio of cold air is incorporated into the hot air duct. The hot air temperature sent to the blast furnace hot air enclosure is controlled to be within 1100 ± 20 °C. The 28 vents send hot air into the blast furnace. Selection: Electric continuous control valve with 220VAC power supply. Control method: Since the adjustment is frequent, automatic control must be put in. PLC-AO output template -4~20mA signal -AI-708J- regulating valve. Single-loop PID control is generally used. Control design AI-708J operator features: (1), integrated handheld communicator and servo amplifier function, and the PLC system works well. (2) It can realize the automatic two-way undisturbed switching of the hand, especially the automatic switching of the hand to make the control more stable and convenient, and simplify the writing of the PLC control program. (3), the function is rich and complete, the panel display is clear at a glance. (4) Adopt modular structure design and connect multiple signal types. (5), stable quality and reliable operation. (6) Anti-interference performance meets the requirements of electromagnetic compatibility (EMC). (7) Convenient parameter lock function. According to the actual situation, it is often necessary for on-site personnel to modify and adjust some parameters. At present, most instruments are locked for all parameters, and the AI-708J operator/servo amplifier can only be displayed by defined parameters or program settings. The parameters can not be displayed and modified, which greatly improves the speed of parameter modification, and avoids the mistaken modification of important parameters, which is greatly welcomed by the staff. (8), the operation is simple and convenient, and the details of the device are introduced in detail. 2, PLC, electric control valve and AI-708J operator / servo amplifier electrical wiring diagram shown in Figure 2: Figure 2 Application Note 1, blast furnace production main screen shown in Figure 3: Figure 3 2, operator application: the blast furnace used There are 4 sets of AI-708J operator/servo amplifier, including 3 sets of top pressure control and 1 set of hot air temperature control. See the main picture of blast furnace production. 3, top pressure, hot air temperature control operation instructions: (1), through the upper machine to control the top pressure or hot air, the operator must be placed in the "automatic" position through the A / M button. Otherwise, place the operator in the "manual" position and adjust the valve opening by "up triangle" or "down triangle". (2) When the valve is automatically controlled: put the “hand automatic switching†button in the “automatic†state in the upper panel operation panel window, and set the production needs in the “automatic setting top pressure (hot air temperature)†input box. If the top pressure or hot air temperature value is entered, the PLC will enter the PID automatic adjustment program. After comparing with the valve position feedback signal, the 4~20mA signal will be dynamically output to the AI-708J, and then output to the electric control valve. (3) When the valve upper machine is manual: put the “hand automatic switch†button in the “manual†state in the upper panel operation panel window. At this time, the data in the “automatic time setting top pressure (hot air temperature)†input box cannot be Function, input the required valve opening value in the "manually set valve position output" input box, the PLC's PID automatic adjustment program stops executing, output 4~20mA signal to AI-708J, and then output to the electric control valve. After the use of the effect blast furnace, due to the excellent external protection provided by the automatic control equipment, the control performance is fully in line with the production process requirements, especially the stable and reliable operation of the AI-708J operator/servo amplifier ensures the important parameters of the blast furnace operation - ―The stable adjustment of the top pressure and hot air temperature makes the blast furnace reach the production efficiency within 15 days, and the utilization coefficient reaches 3.0, which successfully achieves the design goal. Http://news.chinawj.com.cn
This basin mixer tap has hot and cold water to choose temperature as you like. Bathroom Wash Basin Faucet use high quality brass material in basin mixer tap which meet the European requirement . The basin faucet have protection against water block. The life time of switch is 500,000 times.
Basin Faucet,Widespread Bathroom Faucets,Bathroom Faucet,Basin Tap Faucets
HESHAN CAIZUN SANITRAYWARE CO.,LTD , https://www.caizunsanitaryware.com