How to do if the floor heating is not hot

When the cold winter comes, the floor heating as the most comfortable heating system will go into thousands of households. If there is a problem with the floor heating, it will affect people's daily life. Therefore, Xiaobian is not warm to the ground. Question to share the reasons and solutions.


地暖 温暖一生


When the heating pipe of a floor is cleaned and the pipe is not cleanly used for a long time, dirt containing calcium and magnesium will be formed in the pipe, and the thermal conductivity of the pipe will be deteriorated after the dirt is accumulated. Therefore, users are advised to clean the floor heating pipes before or after heating.
If there is air in the heating pipe of the second floor, if the main pole is hot, the backwater bar is not hot. It may be caused by the air in the floor heating pipe, which causes the hot water to enter the circuit and cannot be circulated. In this case, we need to check that the return valve is open (one shape is open, "ten" is closed); if there is air resistance in the geothermal tube, open the bleed valve exhaust until the hot water is released Or use a small valve on the water separator to mediate the cycle of each circuit, so that it can evenly circulate to achieve the desired heating effect.
The three-system circulation difference heating company has a small pressure difference between the supply and return water, and the water flow rate decreases, resulting in the geothermal heat being not hot. This situation can be found in the property.
If the four neighbors are arguing too much, your neighbor or the upstairs and downstairs will have a circulation pump installed on the pipeline, causing the water flow to be too much for his family. The nearby people will naturally be implicated. This household has no way to solve it themselves and can negotiate with neighbors and properties.
If the temperature of the five waters is low, if the indoor temperature is to reach the ideal 18~22 degrees Celsius, the floor heating water temperature must reach above 45 °C. You can measure the temperature of the inlet pipe by yourself or by looking for a professional. If you are not up to standard, you can contact the property in your neighborhood.
Six effective heat dissipation area Small floor heating is radiation heat dissipation, heat is radiated from the bottom up, if the ground cover is more, it will affect heat dissipation. For example, if a large floor bed and wardrobe are placed in the bedroom, the effective heat dissipation area is only 30-40%, which is 50% less than that of a room with legs and furniture. Therefore, too much ground cover will also affect the heat dissipation effect of the floor heating, which is mistaken for the warmth and the heat. In order to make the floor heating better to achieve the cooling effect, it is best to use the furniture with legs, and do not lay carpets on a large area.
7. When improperly installed in the floor heating, some construction workers do not plan construction according to the plan to save floor heating pipes. When the floor heating coil is used, the coil spacing is increased, or the floor laying above the pipeline is too thick, which will affect the heat dissipation efficiency of the floor heating. Dealing with this phenomenon is relatively troublesome. It is necessary to re-lay the floor heating pipe, or reduce the thickness of the floor, waste time, and cause economic loss. Therefore, users are advised to find a professional and regular company to install.
Of course, there are still many reasons that affect the warmth of the floor. I hope that the common problems listed in the small series can help you.
   