Submersible sewage pump basic knowledge and classification of the introduction of the impeller

Submersible sewage pump is a non-clogging pump in a variety of forms: such as submersible and dry two, the most common submersible WQ submersible sewage pump, the most common dry sewage pumps such as W-type horizontal Sewage pump and WL vertical sewage pump two. Mainly used to transport urban sewage, manure or liquid containing fiber. Paper and other solid particles of media, the medium is usually the temperature is not more than 80 ℃. Due to the media being conveyed contain easily entangled or bunched fibers. Therefore, the kind of pump flow channel is easy to block, once the pump is blocked, the pump can not work normally, or even burn the motor, resulting in poor drainage. To urban life and environmental protection have a serious impact. Therefore, the anti-clogging and reliability of the sewage pump is an important factor in the pros and cons. Like other pumps, impellers and pressurized water chambers are the two core components of a sewage pump. The merits of its performance, also on behalf of the pros and cons of pump performance, sewage pump anti-clogging performance, the level of efficiency, as well as cavitation performance, anti-erosion performance mainly by the leaf pump and pressurized water chamber to ensure that the two major components. 1, the structure of the impeller: impeller structure is divided into four categories: leaf type (open, closed), cyclone, runner type (including single and double runner) spiral centrifugal four, open Semi-open impeller manufacturing convenience, when the impeller caused by blockage, it can be very easy to clean and repair, but in the long run, under the erosion of the particles will make the blade and the pressure chamber inside the wall of the gap increases, so that the efficiency reduce. And the increase of clearance will destroy the pressure distribution on the blade. Not only produces a large amount of vortex loss, but also increases the axial force of the pump. At the same time, due to the increased clearance, the stability of the liquid state in the flow passage is destroyed, causing the pump to vibrate. This impeller is not easy to transport Large particles and long fiber media, from the performance point of view, the low efficiency of the impeller type, the highest efficiency of about 92% of ordinary closed impeller, lift curve is relatively flat. 2, swirl impeller: The type of impeller pump, as part or all of the impeller shrinking pressure water chamber runner. So no blockage performance is good, through the ability of particles and the ability of long fibers through. Particles flow in the pressurized water chamber is driven by the vortex generated by the rotation of the impeller. The suspended particles themselves do not generate energy and only exchange energy with the liquid in the flow channel. In the process of flow, suspended particles or long fibers are not in contact with the blade, the blade is more wear and tear less, there is no increase in the gap due to abrasion, long-term operation will not cause a serious decline in efficiency, the use of the Type impeller pumps are suitable for pumping media containing large particles and long fibers. From the performance point of view, the impeller efficiency is low, equivalent to only about 70% of ordinary closed impeller, lift curve is relatively flat. 3, Closed impeller: This type of impeller is more efficient. And in the long run the situation is more stable, the use of the type of impeller pump axial force is small, and can be set in the front and rear cover Vice blades. The auxiliary vanes on the front cover reduce vortex loss at the impeller inlet and wear of the seal ring by the particles. The auxiliary blades on the rear cover not only act to balance the axial forces but also prevent the suspended particles from entering the mechanical seal chamber to protect the mechanical seal. However, the impeller of this type has poor non-blocking property and is easy to wind, so it is not suitable for pumping the treated sewage medium containing large particles (long fibers) and the like. 4, runner-type impeller: This type of impeller bladeless impeller, impeller runner is a from inlet to outlet of a curved runner. It is suitable for pumping medium containing large particles and long fibers. Good anti-blocking. From the performance point of view, the type of high efficiency impeller and ordinary closed impeller or less, but the type of impeller pump head curve is steep drop. The power curve is relatively stable, not easy to produce super power problems, but this type of impeller cavitation performance than ordinary closed impeller, especially suitable for pressure on the pump. 5, Spiral Centrifugal Impeller: This type of impeller blades for the twisted helical blades in the tapered hub body axially extending from the suction port. This type of impeller pump also has the role of volumetric pumps and centrifugal pumps, suspended particles flow in the leaves, do not hit any part of the pump, so good non-destructive. Destructive on the transport of small objects. Due to the helical propulsion and the high permeability of the suspended particles, pumps using this type of impeller are suitable for pumping media containing large particles and long fibers, as well as highly concentrated media. In the transport of media destruction has strict requirements of the occasion has obvious characteristics. From a performance point of view, the pump has a steep drop in head curve, the power curve is relatively flat. Sewage pump pressure chamber is the most common is the volute, built-in submersible pump and more use of radial guide vane or flow guide vane. Volute spiral, ring and intermediary three. Spiral volute is basically not used in the sewage pump. Ring pressure chamber due to simple structure manufacturing convenience in the small sewage pump used more. However, due to the intermediary type (semi-spiral) pressurized water chamber appears annular pressure water chamber application area becomes smaller. Due to the intermediary type pressurized water chamber and the helical high efficiency and high pressure circular chamber water permeability.

Hitachi Escalator Spare Parts

Hitachi Launches New TX Series Escalator for

India, Asia and the Middle East

Hitachi Escalator Parts

Tokyo, August 21, 2017 --- Hitachi, Ltd. (TSE: 6501, [Hitachi") and Hitachi Building Systems Co., Ltd. today announced the launch of the new TX Series escalator for India, Asia and the Middle East. The escalator has already been released in China*1, and will be released in stages across the remainder regions, commencing August 21, 2017.

In July 2016, Hitachi integrated its escalator businesses of Japan and China, consolidating its resources and enhancing its business operations in both countries, centered around its key business location in Guangzhou, China. The new TX Series escalator launched by Hitachi is a model that meets multiple standards in China, India, Asia and the Middle East. The model follows the same concept for the machine room-less elevator for Asia and the Middle East which was launched in September 2016. In addition to conforming to Chinese safety and quality standards for escalator equipment, the TX Series will be manufactured in accordance with Hitachi's own strict standards of safety and quality, adhering to safety standards in all other regions. It also adopts a functional design based on the concept of an escalator that fits closely with the unconscious actions of users, in the pursuit of their ease and comfort.

The TX Series offers flexibility with a selection of various product specifications, as well as its excellent design and safety features, designed to cater to a diverse range of customer needs. It also saves space required for the installation, covering a smaller area in comparison with existing products*2.

Hitachi will begin sales of the TX Series in Thailand, followed by launches in the Philippines, Malaysia and various other regions, and aims to receive orders of 10,000 units in 2018 in China, India, Asia and the Middle East.

Features of the TX Series

  1. Safety
    The TX Series offers various new safety features designed with optimal user safety in mind. The side portions of the steps are 8 mm higher than the central portion to prevent accidents in which a users' shoe can become caught between the step and the skirt (side wall) of the escalator. The new TX series has also been fitted with brushes located at foot level on the left and right skirts to let users know if their foot comes into contact with the side walls. A special finish has also been adopted for the landing plates at the entry and exit points of the escalator to prevent users from slipping when getting on and off the escalator.
  2. Design
    The TX Series adopts a simple and functional design that offers the smoothness, safety and comfort that users unconsciously expect to experience when riding an escalator. For example, by minimizing the size of the metal frame supporting the escalator's balustrades, the TX Series' design maximizes the size of the glass surfaces, and achieves greater simplicity at the entrance and exit points (landings) by reducing the number of recesses and protrusions around the hand rail. Additionally, by expanding the installation space of the light fixture, the TX Series also enables enhanced lighting options for illuminating the entire surroundings of the balustrades.
  3. Space saving
    By shortening the span dimensions*3 by 150 mm, the TX Series has made it possible to install escalators in more confined spaces where installation presents difficulties with conventional product designs.
*1 In China, Hitachi started selling the TX Series escalator in June, 2017.

*2 The made-in-China escalator, [SX series," which is previous model of [TX series."

*3 The span between the beam on upper floor and that on the lower floor of the escalator when the escalator is installed.

Hitachi Escalator Spare Parts,Hitachi Escalator Parts,Hitachi Driven Wheel,Hitachi Step Rollers

CEP Elevator Products ( China ) Co., Ltd. , https://www.zjsmartcommercialescalators.com

This entry was posted in on